Analisis Presisi Aliran Komunikasi Data pada Proses Konversi Analog ke Digital dalam Sistem Monitoring pH Air Berbasis Mikrokontroler Berarsitektur 8-Bit
Kata Kunci:
arsitektur 8-bit, komunikasi data, konversi analog ke digital, presisi ADC, kualitas airAbstrak
Drinking water quality is a critical factor in maintaining human health, with the degree of acidity (pH) serving as one of the primary parameters for determining water suitability for consumption. Digital pH measurement requires a data communication process that begins with the acquisition of analog signals from a sensor and ends with the presentation of information on an output device. This study aims to analyze the precision of the data communication process during Analog-to-Digital Converter (ADC) conversion in a drinking water pH monitoring system based on an 8-bit microcontroller architecture. The data flow begins with an electrochemical pH sensor that responds to hydrogen ions, generating an analog voltage signal inversely proportional to the measured pH value. The signal is then transmitted to the microcontroller's internal ADC, where it is converted into discrete binary data, logically processed using a mathematical regression constant, and subsequently transmitted as visual character instructions to an LCD module, displaying the water condition as Acidic, Neutral, or Alkaline. Empirical evaluation was conducted through calibration using standard pH buffer solutions of pH 4 and pH 7. The results demonstrate that the 8-bit microcontroller data processing algorithm consistently converts signal deviations with a measurement precision ranging from 97.40% to 98.52%. These findings confirm the reliability limit of the 8-bit ADC precision and establish it as a fundamental baseline for liquid analytical instrumentation.
Keywords: 8-bit architecture, data communication, analog to digital conversion, adc precision, water quality
AbstrakKualitas air minum merupakan salah satu faktor penting yang menentukan kesehatan manusia, di mana derajat keasaman (pH) menjadi parameter utama dalam menilai kelayakan konsumsi air. Pengukuran pH secara digital memerlukan proses komunikasi data yang diawali dari akuisisi sinyal analog oleh sensor hingga penyajian informasi pada perangkat keluaran. Penelitian ini bertujuan menganalisis tingkat presisi proses komunikasi data pada konversi Analog-to-Digital (ADC) dalam sistem pemantauan pH air berbasis mikrokontroler berarsitektur 8-bit. Aliran data diawali dari akuisisi sensor pH elektrokimia yang merespons ion hidrogen, menghasilkan sinyal tegangan analog yang berbanding terbalik dengan nilai ukur pH. Sinyal tersebut dialirkan menuju ADC internal mikrokontroler untuk dikonversi menjadi data biner diskrit, diproses secara logis berdasarkan konstanta regresi matematis, dan ditransmisikan sebagai instruksi karakter visual ke modul LCD berupa klasifikasi kondisi Asam, Normal, atau Basa. Evaluasi empiris dilakukan melalui pengujian kalibrasi dengan larutan standar pH buffer 4 dan 7. Hasil analisis menunjukkan algoritma pemrosesan data arsitektur 8-bit mampu mengonversi deviasi sinyal secara konsisten dengan presisi pembacaan sebesar 97,40% hingga 98,52%. Kajian ini membuktikan batas keandalan presisi ADC mikro 8-bit sebagai rujukan utama (baseline) untuk instrumen analitik zat cair.
Unduhan
Referensi
A. Rahman dan H. Santoso, "Sistem Pemantauan Kualitas Air Minum Berbasis Mikrokontroler," Jurnal Teknik Elektro, vol. 10, no. 2, pp. 45-52, 2018.
B. Yanto, "Analisis Parameter pH dan Kekeruhan pada Air Minum Isi Ulang," Jurnal Kesehatan Lingkungan, vol. 5, no. 1, pp. 12-18, 2019.
C. Setiawan, dkk., "Karakterisasi Sensor pH Analog untuk Sistem Monitoring Kualitas Cairan," Jurnal Instrumentasi, vol. 4, no. 3, pp. 110-117, 2020.
D. Pratama, "Perancangan Akuisisi Data Sensor Analog Berbasis Analog-to-Digital Converter (ADC)," Jurnal Teknologi Informasi dan Ilmu Komputer, vol. 8, no. 2, pp. 215-222, 2021.
E. Susanti dan R. Gunawan, "Implementasi Konversi Data Analog ke Digital pada Sistem Pengukuran Terintegrasi," Jurnal Rekayasa Elektrika, vol. 12, no. 4, pp. 99-105, 2017.
F. Kurniawan, "Pemodelan Sensor Kualitas Air untuk Deteksi Kandungan Asam dan Basa Terlarut," Jurnal Fisika dan Aplikasinya, vol. 12, no. 1, pp. 30-36, 2016.
G. Nugroho, "Desain Sistem Komunikasi Data Berbasis I2C dan Paralel pada Modul LCD Display," Jurnal Telekomunikasi dan Komputer, vol. 9, no. 1, pp. 33-40, 2018.
H. Wijaya, "Otomatisasi Sistem Pengukuran Derajat Keasaman (pH) Air Menggunakan Instrumen Sensor Cerdas," Jurnal Fisika Terapan, vol. 15, no. 2, pp. 78-85, 2019.
I. Saputra, dkk., "Pengembangan Sistem Monitoring Kualitas Air Secara Real-Time Menggunakan Mikrokontroler," Jurnal Komputer Terapan, vol. 6, no. 2, pp. 150-158, 2020.
J. Hidayat, "Studi Aliran Data Digital pada Arsitektur Mikrokontroler 8-bit untuk Aplikasi Akuisisi Sensor," Jurnal Teknik Informatika, vol. 14, no. 1, pp. 45-53, 2021.
K. Anwar, "Pemrosesan Sinyal Sensor Kualitas Air untuk Penentuan Status Mutu Air Berbasis Logika Pemrograman," Jurnal Ilmiah Teknologi Informasi, vol. 11, no. 3, pp. 211-219, 2022.
L. Maulana, "Sistem Kalibrasi Otomatis Sensor pH Berbasis Mikrokontroler untuk Industri Air Minum," Jurnal Metrologi, vol. 7, no. 2, pp. 60-68, 2023.
S. M. Ikhsan dan A. Fauzi, "Evaluasi Keandalan Transmisi Data Karakter Antarmuka Sensor pada Layar Penampil," Jurnal Rekayasa Sistem, vol. 10, no. 1, pp. 22-30, 2024.
N. Fitriani, "Pemanfaatan ADC Internal Mikrokontroler AVR untuk Konversi Tegangan Sensor Kimia," Jurnal Elektronika Terapan, vol. 3, no. 4, pp. 18-25, 2016.
O. Permana, "Rancang Bangun Antarmuka Visual Modul LCD 16x2 untuk Monitoring Parameter Lingkungan," Jurnal Instrumentasi dan Kontrol, vol. 5, no. 2, pp. 88-95, 2015.
##submission.downloads##
Diterbitkan
Cara Mengutip
Terbitan
Bagian
Lisensi
Hak Cipta (c) 2026 Reski Yulian Fauzan, Lifwarda Lifwarda, Ricky Wahyudi

Artikel ini berlisensi Creative Commons Attribution 4.0 International License.